Intrapelvic migration of cefalic gama nail screw: report of a challenging case

Authors

DOI:

https://doi.org/10.34019/1982-8047.2021.v47.33842

Keywords:

Foreign-Body Migration, Hip Fractures, Intramedullary Fracture Fixation, Postoperative Complications

Abstract

Introduction: Intrapelvic migration of cephalomedullary head screw is a rare complication which is associated to a high morbidity and mortality rates. Objective: Report a new case of intrapelvic migration of the cephalic screw in order to seek solutions to this complication. Case Report: We present a case of intrapelvic migration of the cephalic screw that occurred at six-week postoperativetly in a 77 year old patient with transtrochanteric fracture treated with cephalomedullary gamma nail who reported multiple falls after the initial surgery. We discuss aspects related to the possible causes of this complication, the planning and execution of treatment, as well as the prognosis of this challenging injury. Conclusion: We realized that it is still necessary to broaden the debate to elucidate the genesis of this complication, since it still remains obscure.

Downloads

Download data is not yet available.

References

Ricci G, Longaray MP, Gonçalves RZ, Neto ASU, Manente M, Barbosa LBH. Avaliação da taxa de mortalidade em um ano após fratura do quadril e fatores relacionados à diminuição de sobrevida no idoso. Ver Bras Ortop. 2012; 47(3):304-9.

Canto RSTC, Sakaki M, Susuki I, Tucci P, Belangero W, Kfuri M et al. Fratura transtrocanteriana. Rev Assoc Med Bras. 2009; 55(6):631-41.

Hesse B, Gachter A. Complications following the treatment of trochanteric fractures with the gamma nail. Arch Orthop Trauma Surg. 2004; 124:692-8.

Davis TR, Sher JL, Horsman A, Simpson M, Poter BB, Checketts RG. Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg Br. 1990; 72-B(1):26-31.

Calvacante ELB, Faria FJ, Rodrigues RA, Ribeiro Filho JEG, Oliveira SG, Elias N. Migração intrapélvica do parafuso cefálico da haste intramedular longa para fêmur proximal: relato de caso. Rev Bras Ortop. 2020; 55(1):121-4.

Weil YA, Gardner MJ, Mikhail G, Pierson G, Helfet DL, Lorich DG. Medial migration of intramedullary hip fixation devices: a biomechanical analysis. Arch Orthop Trauma Surg. 2008; 128:227-34.

Yam M, Kang BJ, Chawia A, Zhang W, Way LG, Xavier RPA et al. Cephalomedullary blade cut‑ins: a poorly understood phenomenon. Arch Orthop Trauma Surg. 2020; 140(12):1939-45.

Thein E, Canniere A, Burn A, Borens O. Medial migration of lag screw after gamma mailing. Injury. 2014; 45:1275-9.

Mohapatra A, Choudhury P. Intrapelvic migration of the antirotation screw from a short proximal femoral nail: an unusual complication of a usually used implant. BMJ Case Rep. 2019; 12.

Chapman T, Zmistowski B, Krieg J, Stake S, Jones CM, Levicof E. Helical blade versus screw fxation in the treatment of hip fractures with cephalomedullary devices: incidence of failure and atypical “medial cutout”. J Orthop Trauma. 2018; 32(8):397.

Law GW, Wong YR, Yew AKS et al. Medial migration in cephalomedullary nail fxation of pertrochanteric hip fractures. Bone Joint Res. 2019; 8:313-22.

Heineman DJ, Buijtenen JM, Heuff G, Derksen EJ, Poll RG. Intra-abdominal migration of a lag screw in gamma nailing: report of a case. Orthop Trauma. 2010; 24:119-22.

Lucke M, Burghardt RD, Siebenlist S, Ganslmeier A, Stockle U. Medial migration of lag screw with intrapelvic dislocation in gamma nailing: a unique problem a report of 2 cases. J Orthop Trauma. 2010; 24(2).

Lozano-Alvarez C, Alier A, Pelfort X, Diaz SM, Pluig L. cervicocephalic medial screw migration after intertrochanteric fracture fixation, otaao 31-a2, using intramedullary nail gamma 3: reporto f 2 cases and literature review. J Orthop Trauma. 2013; 27(11).

Takasago T, Goto T, Toki S, Hamada D, Yoshioka S, Tonogai I et al. Intrapelvic migration of the lag screw in intramedullary nailing. Hindawi. 2014.

Raposo J, Rebelo A, Soares R, Tavares L. Migração medial do parafuso cefálico de cavilha cefalo-medular gamma 3: uma complicação rara e potencialmente fatal. Rev Port Ortopedia Traumatologia. 2015; 23(2):185-94.

Tauber M, Resch H. Sigmoid perforation after medial migration of lag screw in gamma nailing. Arch Orthop Trauma Surg. 2006; 126:118-22.

Georgiannos D, Lampridis V, Bisbinas I. A case report of a rare complication of an intrapelvic migration of the lag screw of a gamma nail: review of the literature. Trauma Cases Ver. 2016, 2:31.

Pinheiro AC, Alpoim B, Félix A, Alves C, Sousa C, Rodrigues A. Migração medial do cravo cefálico de dispositivo cefalomedular Gamma 3: relato de caso. Rev Bras Ortop. 2016; 51(6):720-4.

Kim YW, Kim WY, Kim KJ, Lee SW. intrapelvic migration of the lag screw with wedge wing from dyna locking trochanteric nail: a case report and literature review. Hip Pelvis. 2019; 31(2):110-9.

Published

2021-06-07

How to Cite

1.
Gonçalves Schroder e Souza B, David Oliveira C, Vieira Caires N, Álaf Lucinda de Sá L, Chartuni Teixeira Cury G. Intrapelvic migration of cefalic gama nail screw: report of a challenging case. HU Rev [Internet]. 2021Jun.7 [cited 2024Nov.22];47:1-6. Available from: https://periodicos.ufjf.br/index.php/hurevista/article/view/33842

Issue

Section

Relato de Caso